V/F (I/F) Frequency Pulse Signal Converter

Looking for V/F Frequency Pulse Signal Converter? Look no further. We are a factory specializing in manufacturing high-quality converters.
Request a Quote

PRODUCTS DETAILS

Basic Info.

Model NO.
JSD TAF-1001S
Condition
New
Customized
Non-Customized
Material
Aluminum Alloy
in
0-5V/0-10V/1-5V/4-20mA/0-20mA/0-10mA/0-3.3V
out
0-5kHz/0-10kHz/0-50kHz/0-100kHz/0-200kHz
Power
9-36VDC/24V/15V/12V/5V
High Accuracy
(0.1% F.S, 0.2% F.S)
High Linearity
(0.1% F.S)
Isolation Voltage
3000VDC
Operation Temperature
-45-+85
High Reliability
(Mtbf>50 Wan Hour)
Transport Package
Bubble Bag+Waterproof Bag
Specification
115*100*12.5mm
Trademark
jieshengda
Origin
Shenzhen
Production Capacity
99999

Product Description

V/F(I/F)frequency pulse signal converter
Analog to frequency pulse signal isolation transmitter (V/F converter)

Quotation is not final sale price, please consult sales manager for details
Features:
Low cost, ultra-thin design, international standards DIN35mm rail mounting
Three-port isolation (input, output and power supply )
High accuracy (0.1% F.S, 0.2% F.S)
High linearity (0.1% F.S)
High isolation voltage (3000VDC/60S)
Low temperature drift (80PPM/ºC)
Wide industrial class operation temperature (-45-+85ºC)
High reliability (MTBF>50 Wan hour)
Ultra-wide range power supply design (9-36VDC single power)
International standard signal input (0-5V/0-10V/1-5V/4-20mA/0-20mA/0-10mA/0-3.3V etc.)
International standard signal output (0-5KHz/0-10KHz/0-50KHz/0-100KHz/0-200KHz etc.)

Application:
Sensor signal acquisition, isolation, conversion and transmission
Industrial Automatic control precision measurement and AD acquisition conversion
Analog signal to frequency pulse signal isolation transmitter
Instrumentation equipment ground interference suppression
Data FM phase modulation measurement and control 
Machine process control and digital control technology
Digital instrumentation acquisition isolation and signal conversion
Wireless signal Long-distance transmission without distortion
Analog signal/digital signal conversion
Digital voltmeter, data measurement
Long-distance telemetry remote control device
Medical electronic monitoring, environmental protection equipment long-distance measurement-control  

General Description:
Jieshengda Technology(JSD) JSD TAF-1001S ultra-thin series 1-in-1-out analog to frequency pulse signal converter is a high accuracy isolation transmitter.it can isolate and transform the inputting analog  voltage/current signal into corresponding digital pulse frequency signal . JSD TAF-1001S series V/F frequency pulse signal isolation transmitter adopts ultra-thin shell and ultra-wide operating power supply design, its internal SMD chip technology and modular design makes the performance is more stable and reliable, The new isolation technology makes the product achieve three-port isolation (input, output and power supply),and the isolation voltage between them is up to 3000VDC. The V/F frequency pulse signal converter is widely used in phase modulation, frequency modulation, analog/digital conversion, digital voltmeter, data measurement and remote telemetry remote control device. The product has been corrected, the transmitter isolation adopts international standard DIN35mm rail installation for easy user installation. If the product fails to meet user, we provide customized. if need putting feeding power to two-wire sensor please purchase JSD TAF-1021S series or JSD TAF-2002 2-in-2-out analog to frequency pulse converter, data sheet please contact Jieshengda technology
Selections and Definitions:
Product Selection Parameter List:
Signal input code Power supply code Frequency signal output code
Voltage input code Current input code W:     9-36VDC 1: 0-5KHz (5V voltage pulse)
1: 0-5V A: 0-1mA 1: 24VDC 2: 0-10KHz (5V voltage pulse)
2: 0-10V B: 0-10mA 2: 15VDC 3: 1-5KHz (5V voltage pulse)
3: 0-75mV C: 0-20mA 3: 12VDC 4: 0-5KHz (Open collector)
4: 0-2.5V D: 4-20mA 4: 5VDC 5: 0-10KHz (Open collector)
U: user-defined U: user-defined 6: 1-5KHz (Open collector)
      U: user-defined
Note: When ordering ,please determine input,output and power , special can customize
Selection Example:
Example 1:Signal Input: 0-5V;Signal Output :0-10KHz (5V voltage pulse);Power Supply:9-36VDC; Model:JSD TAF-1001S-1W2
Example 2:Signal Input:4-20mA;Signal Output:0-5KHz (Open collector);Power Supply:24VDC; Model:JSD TAF-1001S-D14
Example 3:Signal Input:1-5V;Signal Output:0-15KHz (5V voltage pulse);Power Supply:9-36VDC; Model:JSD TAF-1001S-UWU
Electrical Characteristics:
Signs Item Test Condition Min Type Max Units
Isolation
characteristics
Isolation voltage AC,50Hz,(Tested for 1minute,humidity<70%,leakage current< 1mA)   3000   V(rms)
Accuracy
characteristics
Non-linearity     0.1 0.2 %FSR
Input characteristics Signal input voltage   0   15 V
current   0   30 mA
Input  voltage     100  
current     100   Ω
Output  characteristics Signal output 1:0-5KHz (5V voltage pulse) High level: 3.0 ~ 5.5V
Low level: < 0.5V
load resistance:>250Ω
2:0-10KHz (5V voltage pulse)
3:1-5KHz (5V voltage pulse)
4:0-5KHz (Open collector) 5 12 24 VDC
5:0-10KHz (Open collector)
6:1-5KHz (Open collector)
Response time     ≤50   mS
Power
input
characteristics
Power supply voltage   5 24 36 VDC
Power loss     1   W
Rage   -10   +10 %
Other characteristics operating temperature   -45   85 ºC
storage temperature   -55   105 ºC
size   115x100x12.5 mm
weight       100 g
Note: When ordering, please determine input,output and power, special can customize
Pin Function Description:
Signal Type Pin Function Description Pin Function Description Package
Frequency Output 1 Power + 5 Signal Out + Standard
DIN35
Rail
Mounting
2 Power - 6 Signal Out -
3 Signal In + 7 No pin (NC)
4 24VDC Power out + 8 No pin (NC)
Open collector output recommended resistance table:
 
Power R(Resistance)
+5VDC 2
+12VDC 5.1
+15VDC 6.8
+24VDC 15
V/F (I/F) Frequency Pulse Signal Converter
Notes
:

1,Please read the user manual carefully before using. If any question please contact our technical support department.
2,Please do not use this product in hazardous area. The power supply of this product should be DC power source. It is forbidden to use 220VAC power supply. ''NC" pin must not be connected to any external circuit, otherwise it will damage the product itself;
3,This product layout dimension are "mm" and "inch" as the unit, within "[]" are inch;
4,Calculating from the date of delivery, during normal use of the product, any quality problems are free repair or replacement by company during 3 years warranty,
5,the product is strictly forbidden demolish without permission for not damage
6,All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
7,In this datasheet, all the test methods of indications are based on corporate standards.
V/F (I/F) Frequency Pulse Signal Converter
V/F (I/F) Frequency Pulse Signal Converter
V/F (I/F) Frequency Pulse Signal Converter

V/F (I/F) Frequency Pulse Signal Converter

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours