20W 43dBm 100MHz to 2GHz Pulse GaN RF Broadband Power Amplifier/PA Module

Introducing our 20W 43dBm Pulse GaN RF Broadband Power Amplifier Module, covering 100MHz to 2GHz. We are a factory specializing in high-quality RF products.
Request a Quote

PRODUCTS DETAILS

Basic Info.

Model NO.
ET-PAU20W
Output Power
5/10/20/40/50/100/200/500 Watts
Gain
40- 50dB or Customized
Gain Adjustment Range(dB)
>30/1dB Step or Customized
RF Connector
SMA-50k or Other Customized
Gain Flatness(dB)
1(Max)
Impedance(Ohm)
50
Power Current
<5.5A
Monitor Interface
RS-485 or RS232 or Other Customized
Transport Package
Carton Packing
Specification
5/10/20/40/50/100/200/500 watts
Trademark
ETENDA
Origin
Shenzhen
Production Capacity
500PCS/Month

Product Description

20W 43dBm 100MHz to 2Ghz Pulse GaN RF Broadband Power Amplifier                   
All the parameters of PA can be customized depend on your request, if you have any customized parameters pls contact us freely

Technical Specifications
 
Frequency(MHz) 100-2000M
Input Power ≤20dBm
Output Power(dBm) 43±1(20W )
ALC Range(dB) ≥25
In-Band ripple(dB) ≤2
Gain(dB) 43 or Customized
Gain Adjustment range(dB) >31/1dB step or Customized
Gain Adjustment Linearity(dB) ≤±1
Gain Flatness(dB) ±0.5(Max)
Impedance(ohm) 50
VSWR ≤1.4:1
Voltage(V) DC+28
Power current ≤8A
RF Connector SMA-50K or other Customized
Monitor interface RS-485 or RS232 or other Customized
Monitoring communication protocols Use Manufacturers protocol or Customized
Working Temperature -40~+65 degree
Storage Temperature -55 to +85 degree
Operating Humidity 0 to 90%, relative
Surface Color Metal color conductive oxide and other color customized
weight  ≤2.5KG
Remark Module with output short circuit or open circuit protection

Monitoring Function Description:
No. Monitoring function Description
1 query PA ALARM When an alarm amplifier failure
2 SWR ALARM Amplifier output reflection is too large, VSWR exceeds 3:1, an alarm is generated
3 Over temperature alarm Module internal temperature exceeds 85 ºC, generates an alarm and turn off the amplifier until the temperature returns to below 65 ºC, re-open the amplifier
4 Over  output power alarm When the output power exceeds the nominal full power 2dB is an alarm
5 Input power detection Accuracy of ± 1dB
6 Reverse power detection Accuracy of ± 1dB
7 output power detection Detecting the actual output power amplifier,Accuracy of ± 1dB
8 Temperature detection Detection module operating temperature, detection range: -25 ~ +90 ºC, Accuracy of ± 3 ºC
10 SWR Detecting amplifier output port VSWR range of 1.2 ~ 4.0
11 query and set PA attenuator Set and query Set and query the value of ATT
12 PA switching query and set Query and set the state open tube amplifier
  20W 43dBm 100MHz to 2GHz Pulse GaN RF Broadband Power Amplifier/PA Module
 
 
20W 43dBm 100MHz to 2GHz Pulse GaN RF Broadband Power Amplifier/PA Module
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours